CIP Equipment

CIP Disinfection for Food, Beer & Beverage Industry

The use of Electrolyzed Water as an Anolyte or Catalyst allows for Clean-In-Place hygiene applications to remove unwanted microorganisms from contact surfaces in the food and beverage industry.
The multiple applications allow the use of anolyte for disinfection and catolite as a washing fluid. Therefore, there is a distinct need in the food processing, beer, and beverage industries for generators capable of producing both Anolyte and Catalyte.
The Envirolyte CIP type of generators is ideal for both this area and other types of market (hotels, schools, government facilities, military bases, prisons, cruise ships, etc.) These generators are easy to install, operate, and easy to maintain, increasing safety and reducing operating costs.
The Envirolyte CIP range of anolite/catolite generators has been developed in cooperation with our partners for the food and beverage processing market and is only available in the low-salt configuration.

CIP generators are a significant advancement in anolyte and catolite production technology. Its main features are:

While these anolyte and catolite generators were designed for the beverage and food markets, they can be used in any situation where anolyte and catolite solutions are required for effective cleaning and sanitizing operations.

Specifications of Envirolyte CIP Anolite/Catolite Generators

Specifications/ModelsEnvirolite CIP-20/20Envirolite CIP-40/40Envirolite CIP-100/100Envirolite CIP-200/200Envirolite CIP-300/300
Output Capacity

~20 LPH ANW anolyte with pH ~6.0 – 7.0 (can be regulated) and ~500-550 ppm FAC;

~20 LPH of catholyte with pH ~ 12.2-12.5 and ~ 0.8-1.0 g/L of NaOH

~40 LPH of ANW anolyte with pH ~ 6.0 – 7.0 (can be regulated) and ~500-550 ppm FAC;

~40 LPH of catholyte with pH ~ 12.2-12.5 and ~ 0.8-1.0 g/L of NaOH

~100 LPH ANW anolyte with pH ~6.0 – 7.0 (can be regulated) and ~500-550 ppm FAC;

~100 LPH of catholyte with pH ~ 12.2-12.5 and ~ 0.8-1.0 g/L of NaOH

~200 LPH ANW anolyte with pH ~6.0 – 7.0 (can be regulated) and ~500-550 ppm FAC;

~200 LPH of catholyte with pH ~ 12.2-12.5 and ~ 0.8-1.0 g/L of NaOH

~300 LPH ANW anolyte with pH ~ 6.0 – 7.0 (can be regulated) and ~500-550 ppm FAC;

~300 LPH of catholyte with pH ~ 12.2-12.5 and ~0.8-1.0 g/L of NaOH

Production modeEither independent production of anolyte and catolite or simultaneous production of both fluids. Operation is controlled by the level switches in the anolyte and catolite tanksEither independent production of anolyte and catolite or simultaneous production of both fluids. Operation is controlled by the level switches in the anolyte and catolite tanksEither independent production of anolyte and catolite or simultaneous production of both fluids. Operation is controlled by the level switches in the anolyte and catolite tanksEither independent production of anolyte and catolite or simultaneous production of both fluids. Operation is controlled by the level switches in the anolyte and catolite tanksEither independent production of anolyte and catolite or simultaneous production of both fluids. Operation is controlled by the level switches in the anolyte and catolite tanks
Power Supply220VAC / One Phase / 50-60Hz

220VAC / One Phase / 50-60Hz

 

220VAC / One Phase / 50-60Hz380 VAC / Three Phase / 50-60 Hz380 VAC / Three Phase / 50-60 Hz
Salt consumption to generate ~500 ppm FAC and catholyte with ~1.0 g/L NaOH~1.5 g per 1 L of anolyte and ~-3.8 g per 1 L of catholyte

~1.5 g per 1 L of anolyte and ~-3.8 g per 1 L of catholyte

 

~1.5 g per 1 L of anolyte and ~-3.8 g per 1 L of catholyte~1.5 g per 1 L of anolyte and ~-3.8 g per 1 L of catholyte~1.5 g per 1 L of anolyte and ~-3.8 g per 1 L of catholyte
Semi-automatic washing+++++
Acid pump to wash the cells+++++
Brine Pump+++++
Peristaltic Control Pump for Anolyte Generator Cathodic Chamber+++++
Peristaltic Control Pump for Anode Chamber of Catalyte Generator+++++
Peristaltic control pump for anolyte pH regulation+++++
Inlet Valves+++++
Flow & Pressure Switches/Controllers

+

separate for each platform

+

separate for each platform

+

separate for each platform

+

separate for each platform

+

separate for each platform

Conductivity sensor to control saturation and brine consumption+++++
Level switch+ Independent for anolith and catolite tanks+ Independent for anolith and catolite tanks+ Independent for anolith and catolite tanks+ Independent for anolith and catolite tanks+ Independent for anolith and catolite tanks
Burst level switchOptionalOptionalOptionalOptionalOptional
Audible overflow alarmOptionalOptionalOptionalOptionalOptional
Extra 230 VAC socket in the electrical panelOptionalOptionalOptionalOptionalOptional
DurabilityAble to withstand harsh conditions such as dust and high humidityAble to withstand harsh conditions such as dust and high humidityAble to withstand harsh conditions such as dust and high humidityAble to withstand harsh conditions such as dust and high humidityAble to withstand harsh conditions such as dust and high humidity
Cell type

1 x R-40ANW

1 x R-60C

1 x R-80ANW

1 x R-120C

1 x R-120ANW

1 x R-300C

1 x R-200ANW

1 x R-400C

1 x R-300ANW

1 x R-600C

Life expectancy of electrodes and membrane~ 5 – 7 years~ 5 – 7 years~ 5 – 7 years~ 5 – 7 years~ 5 – 7 years
AccessoriesLLDPE Tubing + Kynar FittingsLLDPE Tubing + Kynar FittingsLLDPE Tubing + Kynar FittingsLLDPE Tubing + Kynar FittingsLLDPE Tubing + Kynar Fittings

PLC Control:

Unitronics/Vision 130 or Vision 280

+++++
Remote Control Features

Optional

Ethernet or GSM or Modbus – needs to be specified when ordering.

Optional

Ethernet or GSM or Modbus – needs to be specified when ordering.

Optional

Ethernet or GSM or Modbus – needs to be specified when ordering.

Optional

Ethernet or GSM or Modbus – needs to be specified when ordering.

Optional

Ethernet or GSM or Modbus – needs to be specified when ordering.

Economy

How much can I save with Envirolyte solutions?

Calculate and find out how cost-effectiveness makes all the difference

Responsibility

How toxic are my current processes?

Evaluate your current cleaning and disinfection processes compared to the solutions offered by Envirolyte.

Challenge

Take the Challenge of the Gallon

Sign up to participate in the challenge and receive free samples for testing.
(954) 712-7409